Manual J or an equivalent, room-by-room heat loss and gain calculation is not paperwork for the file; it is the steering wheel for the entire job. Without it, sizing guesses lead to short cycling, humidity problems, and inconsistent temperatures. Request the full report, ask about infiltration and window assumptions, and verify design temperatures for your climate. A homeowner in Denver avoided oversizing simply by insisting on the printed pages and challenging default infiltration rates.
Great plans consider where linesets can run cleanly, where condensate can drain by gravity, how snow drifts, and what neighbors hear at night. Look for clearance to service panels, coil cleaning access, and future filter changes without gymnastics. Photograph attic pathways, measure soffit openings, and note breaker space in the panel. Catching a tight attic hatch or a crowded electrical panel early can prevent shortcuts later that quietly erode efficiency and reliability.
The temptation to go bigger for safety often backfires. Short run times mean uneven temperatures, poor humidity control, higher noise, and more wear on components. Use performance tables at your design temperature, not 47°F marketing numbers. One coastal family discovered their oversized unit caused clammy rooms; downsizing and increasing run time fixed comfort and cut energy use. Remember, consistent, longer cycles are a friend to both comfort and the compressor’s longevity.
The temptation to go bigger for safety often backfires. Short run times mean uneven temperatures, poor humidity control, higher noise, and more wear on components. Use performance tables at your design temperature, not 47°F marketing numbers. One coastal family discovered their oversized unit caused clammy rooms; downsizing and increasing run time fixed comfort and cut energy use. Remember, consistent, longer cycles are a friend to both comfort and the compressor’s longevity.
The temptation to go bigger for safety often backfires. Short run times mean uneven temperatures, poor humidity control, higher noise, and more wear on components. Use performance tables at your design temperature, not 47°F marketing numbers. One coastal family discovered their oversized unit caused clammy rooms; downsizing and increasing run time fixed comfort and cut energy use. Remember, consistent, longer cycles are a friend to both comfort and the compressor’s longevity.

Manufacturer tables specify maximum line lengths, vertical separation, and sometimes traps to ensure oil returns reliably. Deviating without engineering support risks poor lubrication and premature failures. Ask how your route fits within those limits and whether added refrigerant is required. A careful installer rerouted lines to shorten an attic run by eight feet, staying within spec and preventing a tricky trap. Those boring details quietly extend compressor life and maintain consistent capacity year after year.

Pulling to a deep vacuum with a quality pump and a micron gauge proves dryness and tightness. Target below 500 microns, isolate, and confirm it holds. Sweep with nitrogen to carry out moisture. Skipping core removal or relying on manifold gauges alone invites acid and future leaks. A shop that adopted strict evacuation procedures cut warranty compressors dramatically, turning tedious patience into measurable reliability and fewer unhappy phone calls during the first hot weekend.

Pressure test with dry nitrogen, soap every joint, and use an electronic detector for final assurance. Document pressures and hold times. Charging by weight and fine-tuning with superheat or subcool confirms accuracy. A homeowner in Boise asked for test photos and later avoided a ceiling stain when a tiny braze flaw was caught early. Verification does not slow progress—it prevents heartbreak, protects finishes, and saves both installer and homeowner from expensive, stressful return visits.